13
items or under active stones and highly mineralized soils.
In this case, if, for example, an object (stone, ceramics or some iron) has been memorized,
with own signal of -28, the device will not react to any signals smaller than -28, and
each signal greater than -28 will be registered with sound, as the objects with more
positive signal― (from -27 to 0“) will be signalized with a low tone, and all positive
ones with high tone. If from the menu for Low tone a value of „1“ has been selected,
for the negative signals there will not be low tone and the device will react with high tone
only for the positive signals, i. e., for the nonferrous metals.
Analogue is the operation of the device also when working in an „auto discr +“
mode all metals with a signal more positive than the memorized one will be signalized,
and all having values lower than the memorized, will be eliminated.
The difference between theauto discr + and “AUTO DISCR + modes is that at a
selected mode with capital letters the device operates more effectively for bigger objects
and can successfully memorize and eliminate undesired bigger objects or more active soils
(in REJECT“ mode). When operating in „auto discr + / „reject“ mode, the device can
successfully memorize and eliminate undesired smaller objects for example wire and
small nails, and to effectively search for coins, rings or other small objects, but in this
mode very big objects or very high mineralization of soil can provoke undesired misleading
signal. In such cases it is recommended the device to operate in AUTO DISCR + mode.
The modes with + can be selected by pressing the button SELECT“ until the
discr parameter appears, and one has to choose either discr 3 for auto discr + or
discr 4AUTO DISCR +.
Switching between the modes with + and without + can be done also during
work with pressing and holding of the buttonh VCO / DISCR for more than 3 sec., but
this can be done only in the sub modes reject / REJECT.
3. Balancing to the background of the soil in the discrimination modes.
Usually, light weak mineralized soils have their own signal of up to Level: 15
20“. On them, one can work in a "NORMAL DISCR" mode, and the only balancing which can
Page view 12